A comparative study of new and current methods for dental micro-CT image denoising

Affiliations

01 January 2016

-

doi: 10.1259/dmfr.20150302


Abstract

Objectives: The aim of the current study was to evaluate the application of two advanced noise-reduction algorithms for dental micro-CT images and to implement a comparative analysis of the performance of new and current denoising algorithms.

Methods: Denoising was performed using gaussian and median filters as the current filtering approaches and the block-matching and three-dimensional (BM3D) method and total variation method as the proposed new filtering techniques. The performance of the denoising methods was evaluated quantitatively using contrast-to-noise ratio (CNR), edge preserving index (EPI) and blurring indexes, as well as qualitatively using the double-stimulus continuous quality scale procedure.

Results: The BM3D method had the best performance with regard to preservation of fine textural features (CNREdge), non-blurring of the whole image (blurring index), the clinical visual score in images with very fine features and the overall visual score for all types of images. On the other hand, the total variation method provided the best results with regard to smoothing of images in texture-free areas (CNRTex-free) and in preserving the edges and borders of image features (EPI).

Conclusions: The BM3D method is the most reliable technique for denoising dental micro-CT images with very fine textural details, such as shallow enamel lesions, in which the preservation of the texture and fine features is of the greatest importance. On the other hand, the total variation method is the technique of choice for denoising images without very fine textural details in which the clinician or researcher is interested mainly in anatomical features and structural measurements.

Keywords: X-ray microtomography; computer-assisted image processing; dental; image quality enhancement; noise.


Similar articles

Ultra-low-dose CT image denoising using modified BM3D scheme tailored to data statistics.

Zhao T, Hoffman J, McNitt-Gray M, Ruan D.Med Phys. 2019 Jan;46(1):190-198. doi: 10.1002/mp.13252. Epub 2018 Nov 19.PMID: 30351450

Micro-CT based quantitative evaluation of caries excavation.

Neves Ade A, Coutinho E, Vivan Cardoso M, Jaecques SV, Van Meerbeek B.Dent Mater. 2010 Jun;26(6):579-88. doi: 10.1016/j.dental.2010.01.012. Epub 2010 Mar 29.PMID: 20347481

Improvement of image quality in PET using post-reconstruction hybrid spatial-frequency domain filtering.

Arabi H, Zaidi H.Phys Med Biol. 2018 Oct 24;63(21):215010. doi: 10.1088/1361-6560/aae573.PMID: 30272565

Patch-based models and algorithms for image denoising: a comparative review between patch-based images denoising methods for additive noise reduction.

Alkinani MH, El-Sakka MR.EURASIP J Image Video Process. 2017;2017(1):58. doi: 10.1186/s13640-017-0203-4. Epub 2017 Aug 24.PMID: 32010201 Free PMC article. Review.

A Survey on State-of-the-Art Denoising Techniques for Brain Magnetic Resonance Images.

Mishro PK, Agrawal S, Panda R, Abraham A.IEEE Rev Biomed Eng. 2022;15:184-199. doi: 10.1109/RBME.2021.3055556. Epub 2022 Jan 20.PMID: 33513109 Review.


Cited by

Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density.

Gaêta-Araujo H, Nascimento EHL, Brasil DM, Madlum DV, Haiter-Neto F, Oliveira-Santos C.Imaging Sci Dent. 2020 Jun;50(2):153-159. doi: 10.5624/isd.2020.50.2.153. Epub 2020 Jun 18.PMID: 32601590 Free PMC article.

Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint.

Iskanderani D, Nilsson M, Alstergren P, Shi XQ, Hellen-Halme K.Dentomaxillofac Radiol. 2020 Sep 1;49(6):20190495. doi: 10.1259/dmfr.20190495. Epub 2020 Apr 9.PMID: 32250642 Free PMC article.

Effect of micro-computed tomography reconstruction protocols on bone fractal dimension analysis.

Gaêta-Araujo H, Oliveira-Santos N, Brasil DM, do Nascimento EHL, Madlum DV, Haiter-Neto F, Oliveira-Santos C.Dentomaxillofac Radiol. 2019 Dec;48(8):20190235. doi: 10.1259/dmfr.20190235. Epub 2019 Aug 13.PMID: 31408366 Free PMC article.

Modelling of stress distribution and fracture in dental occlusal fissures.

Wan B, Shahmoradi M, Zhang Z, Shibata Y, Sarrafpour B, Swain M, Li Q.Sci Rep. 2019 Mar 18;9(1):4682. doi: 10.1038/s41598-019-41304-z.PMID: 30886223 Free PMC article.

Microcomputed Tomography Calibration Using Polymers and Minerals for Enamel Mineral Content Quantitation.

Alyahya A, Alqareer A, Swain M.Med Princ Pract. 2019;28(3):247-255. doi: 10.1159/000499186. Epub 2019 Mar 1.PMID: 30820021 Free PMC article.


KMEL References