Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides
Affiliations
Affiliations
- Kuwait University, Faculty of Dentistry, Safat, Kuwait.
- University of the Pacific, Arthur A. Dugoni School of Dentistry, San Francisco, Calif.
Abstract
The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.
Keywords: CAD/CAM; guided surgery; immediate placement implants; stereolithography.
Similar articles
Alzoubi F, Massoomi N, Nattestad A.J Oral Implantol. 2016 Oct;42(5):406-410. doi: 10.1563/aaid-joi-D-16-00016. Epub 2016 Jun 8.PMID: 27276111
Accuracy of virtually planned and CAD/CAM-guided implant surgery on plastic models.
Pettersson A, Kero T, Söderberg R, Näsström K.J Prosthet Dent. 2014 Dec;112(6):1472-8. doi: 10.1016/j.prosdent.2014.01.029. Epub 2014 Jun 30.PMID: 24993374
Liu H, Liu DX, Wang KT, Wang CL, Zhao Z.Hua Xi Kou Qiang Yi Xue Za Zhi. 2010 Oct;28(5):517-21.PMID: 21179688 Chinese.
CAD / CAM dental systems in implant dentistry: update.
Fuster-Torres MA, Albalat-Estela S, Alcañiz-Raya M, Peñarrocha-Diago M.Med Oral Patol Oral Cir Bucal. 2009 Mar 1;14(3):E141-5.PMID: 19242395 Review.
Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L.Clin Oral Implants Res. 2017 May;28(5):602-612. doi: 10.1111/clr.12841. Epub 2016 Apr 8.PMID: 27062555 Review.
Cited by
Pirooz P, Atri F, Gholami P, Bayat M.Maxillofac Plast Reconstr Surg. 2023 May 17;45(1):19. doi: 10.1186/s40902-023-00387-5.PMID: 37195351 Free PMC article.
Raabe C, Schuetz TS, Chappuis V, Yilmaz B, Abou-Ayash S, Couso-Queiruga E.Int J Implant Dent. 2023 Feb 7;9(1):4. doi: 10.1186/s40729-023-00470-6.PMID: 36749441 Free PMC article.
Application of measurable surgical guides in immediate implant placement and immediate restoration.
Wang Y, Xie C, Zhang Y, Zhang Y, Fang T, Yu H.Hua Xi Kou Qiang Yi Xue Za Zhi. 2022 Dec 1;40(6):731-739. doi: 10.7518/hxkq.2022.06.017.PMID: 36416329 Free PMC article. Chinese, English.
Huang L, Zhang X, Mo A.Materials (Basel). 2021 Aug 17;14(16):4631. doi: 10.3390/ma14164631.PMID: 34443154 Free PMC article.
Advantages and limitations of implant surgery with CAD/CAM surgical guides: A literature review.
Unsal GS, Turkyilmaz I, Lakhia S.J Clin Exp Dent. 2020 Apr 1;12(4):e409-e417. doi: 10.4317/jced.55871. eCollection 2020 Apr.PMID: 32382391 Free PMC article. Review.